Fill out the form below to help us pair you with the right expert. We’ll prepare the information you request, then contact you as soon as possible.
TEROS 10 Tech Specs
TECHNICAL SPECIFICATIONS
Volumetric Water Content
Range
Mineral Soil Calibration: 0.0000 – 0.6400 m3/m3
Soilless Media Calibration: 0.0000 – 0.7000 m3/m3
Apparent Dielectric Permittivity (εa): 1 (air) to 80 (water)
NOTE:The VWC range is dependent on the media the sensor is calibrated to. A custom calibration will accommodate the necessary ranges for most substrates.
Resolution
0.0010 m3/m3
Accuracy
Mineral Soil Calibration: ±0.03 m³/m³ typical in mineral soils that have solution EC <8 dS/m
Soilless Media Calibration: ±0.05 m³/m³ typical in media that has a solution EC <8 dS/m
Medium Specific Calibration: ±0.01–0.02 m³/m³ in any porous medium
Data acquisition systems capable of switched 3.0–15 VDC excitation and single-ended voltage measurement at greater than or equal to 12-bit resolution. See compatibility chart
Physical Specifications
Dimensions
Length: 5.1 cm (2.02 in)
Width: 2.4 cm (0.95 in)
Height: 7.5 cm (2.95 in)
Needle Length
5.4 cm (2.11 in)
Operating Temperature Range
Minimum: -40.00 °C
Typical: NA
Maximum: 60.00 °C
NOTE:Sensors may be used at higher temperatures under certain conditions; Contact Customer Support for assistance.
Cable Length
5 m (standard)
40 m (maximum custom cable length)
NOTE: Contact Customer Support if a nonstandard cable length is needed.
Cable Diameter
0.165 ± .004 (4.20 ± .10 mm) with min. jacket of .030 (.76 mm)
Connector Types
3.5-mm stereo plug connector or stripped and tinned wires
Stereo Plug Connector Diameter
3.5 mm
Conductor Gauge
22 AWG/24 AWG drain wire
Electrical and Timing Characteristics
Supply Voltage (VIN to GND)
Minimum: 3.0 VDC
Typical: NA
Maximum: 15.0 VDC
Measurement Duration
Minimum: 10 ms
Typical: NA
Maximum: NA
Other
Compliance
EM ISO/IEC 17050:2010 (CE Mark)
2014/30/EU 2011/65/EU
EN61326-1:2013 EN55022/CISPR 22